Studi Pengujian Karakteristik Minyak Nabati Terhadap Tegangan Tembus Sebagai Alternatif Pengganti Minyak Trafo
Abstract
The increase in the use of mineral oil or petroleum as insulation for electrical equipment is increasing every year due to the function to withstand the breakdown voltage on electrical equipment, namely the transformer, this mineral oil can withstand a breakdown voltage of >30 KV/2.5mm according to the standards set by the PLN. Based on data obtained on January 9, 2021, from the Indonesian Ministry of Energy and Mineral Resources, it is stated that Indonesia's oil reserves will run out in 9.5 years with the assumption that no new reserves will be discovered in the future. This research was conducted to test several vegetable oils, to be able to reduce or replace the function of mineral oil which is getting thinner every year. The method used in this test is a direct test method with vegetable oils such as candlenut oil, castor oil, and coconut oil on the breakdown voltage. In the research and testing that has been done on coconut cooking oil, candlenut oil and castor oil, the breakdown voltage values obtained are 12.93 kV, 14 kV, and 68.73 kV. So it can be said based on the results of the tests carried out that castor oil has a breakdown voltage of 68.73 kV, it means that it is possible to be used as an alternative to existing transformer oil, because it has a breakdown voltage according to the standards set by PLN.
Keywords
Full Text:
PDF (Indonesian)References
Adibah, F. (2016). Studi Karakteristik Minyak Jarak Sebagai Alternatif Isolasi Cair Pada Transformator Daya Menggunakan Destilasi Vakum Dengan Variasi Fenol. 1–55.
Dhofir, M., Dona, N. R., Wibawa, U., & Hasanah, N. (2017). Minyak kelapa beraditif minyak zaitun sebagai isolasi peralatan tegangan tinggi. Eeccis, 11(2), 69–76.
Kurrahman, H. T., Abduh, S. (2016). Studi tegangan tembus minyak kamiri sunan sebagai alternatif pengganti minyak transformator daya. JETri, 13(2), 11–28.
Putra, R. K., & Murdiya, F. (2017). Karakteristik Tegangan Tembus Arus Bolak Balik Pada Minyak Jarak Pagar (Jatropha curcas) Sebagai Alternatif Isolasi Cair. Jom FTEKNIK, 4(2), 1–11.
Winanta, I. N. O., Agung, A., Amrita, N., & Ariastina, W. G. (2019). Studi Tegangan Tembus Minyak Transformator. 6(3).
Muhaimin. (1999). Bahan-Bahan Listrik. Jakarta: Pradnya Paramita
Abduh, Syamsir. (2003). Teori Kegagalan Isolasi. Jakarta: Universitas Trisakti.
Naidu, M. S., dan V Kamaraju. (1996). High Voltage Engineering Second Edition. United States: TheaMcGraw Hill.
Marsudi, Djiteng, (2011). “Pembangkitan Energi Listrik”. Erlangga
Modul Praktikum Teknik Tegangan Tinggi, Laboratatotium Tetangan Tinggi. IT-PLN
IEEE C2. (2007). National Electrical Safety Code. Washington DC: Jefferson Country Public Library. (standar minyak)
Garniwa, I., & S, J. F. (2011). Analisis Pengaruh Kenaikan Temperatur Dan Umur Minyak Transformator Terhadap Degradasi Tegangan Tembus Minyak Transformator. Jurnal Teknik Elektro, Universitas Indonesia. Depok
AS, Nizar. R., & Deki, P. (2021). Pengujian Tegangan Tembus Pada Minyak Trafo. Sinusoida, 23(2), 20-32.
Setiyandani, E., & Prasetyono, S. (2021). Uji Karakteristik Bio Minyak Trafo Berbahan Dasar Minyak Kemiri Sunan dengan Penambahan Zat Aditif Butylated Hydroxytoulene (BHT) Sebagai Alternatif Isolasi Cair Transformator Daya 150 KVA. Jurnal Intake: Jurnal Penelitian Ilmu Teknik dan Terapan, 12(1), 1-8.
Winanta, I. N. O., Amrita, A. A. N., & Ariastina, W. G. (2019). Studi Tegangan Tembus Minyak Transformator. Jurnal SPEKTRUM Vol, 6(3).
DOI: http://dx.doi.org/10.36055/setrum.v11i1.14051
Refbacks
- There are currently no refbacks.