Data Communication Between PLC Using Internet-Based Modbus Protocol

Hudzaifi Fuad Ibrahim, Asep Andang, Firmansyah MSN

Abstract


This study aims to analyze the performance of communication between Programmable Logic Controller (PLC) using Modbus TCP protocol over the internet. Mitsubishi FX5U PLC as Modbus client and Omron CP1L-E PLC as Modbus server. Tests were carried out by measuring quality of service (QoS) parameters such as delay, jitter, throughput, and packet loss according to TIPHON standards, with variations in the delay time of each request, namely 10 ms, 25 ms, 50 ms, 70 ms, 75 ms, 80 ms, and 100 ms. The test results show that the delay is between 36 ms to 61 ms with an average of 45 ms, which gives a TIPHON index value of 4. Jitter varies between 10 ms to 86 ms with an average of 56 ms, giving a TIPHON index value of 3. Packet loss is mostly 0%, except at delay of 10 ms and 25 ms with a result of 0.1%, giving a TIPHON index value of 4. Thus, the delay time of 75 ms is the most optimal choice with a delay value of 40 ms, jitter 68 ms, and packet loss 0%. This inter-PLC communication system is proven to be optimal and can be implemented in an industrial environment with good performance.

Keywords


PLC; Modbus TCP; delay; jitter; throughput; packet loss; industrial communication

Full Text:

PDF

References


J. F. S. R. S. F. S. U. Birgit Vogel-Heuser, “Challenges for Maintenance of PLC-Software and Its Related Hardware for Automated Production Systems: Selected Industrial Case Studies,” 2015. http://dx.doi.org/10.1109/ICSM.2015.7332487

S. Jaloudi, “Communication protocols of an industrial internet of things environment: A comparative study,” Future Internet, vol. 11, no. 3, 2019, doi: 10.3390/fi11030066.

Y. Li and L. Yao, “Research on Ethernet Communication and Remote Control of PLC and PC,” 2016. http://dx.doi.org/10.2991/icmemtc-16.2016.156

Frank Petruzella, “Programmable Logic Controllers,” 2017.

Mitsubishi Electric, “MELSEC iQ-F FX5U User’s Manual (Hardware),” 2016. Available: www.mitsubishifa.co.th

Mitsubishi Electric, “MELSEC iQ-F FX5 User’s Manual (Ethernet Communication),” 2016. Available: dl.mitsubishielectric.com

Omron Corporation, OPERATION MANUAL SYSMAC CP Series. 2014. Available: www.ia.omron.com

Mitsubishi Electric, “MELSEC iQ-F FX5 User’s Manual (MODBUS Communication),” 2016. Available: dl.mitsubishielectric.com

L. Xuan and L. Yongzhong, “Research and Implementation of Modbus TCP Security Enhancement Protocol,” in Journal of Physics: Conference Series, Institute of Physics Publishing, Jun. 2019. doi: 10.1088/1742-6596/1213/5/052058.

S. O. Wilson, A. Chancsig, R. Gamboa, D. Tipn, and S. Elizabeth, “Control and Monitoring of Electrical Variables of a Level Process using Modbus RTU-TCP/IP Industrial Communication,” Indian J Sci Technol, vol. 11, no. 32, pp. 1–12, Aug. 2018, doi: 10.17485/ijst/2018/v11i32/131113.

A. B. Pratomo DEVELOPING A FIREWALL SYSTEM ON A COMPUTER NETWORK BASED ON MIKROTIK ROUTEROS,” vol. 1, no. 2, 2023, doi: 10.59688/bufnets.

X. Zou et al., “Pixel-level Bayer-type colour router based on metasurfaces,” Nat Commun, vol. 13, no. 1, Dec. 2022, doi: 10.1038/s41467-022-31019-7.

R. Wulandari, “ANALISIS QoS (QUALITY OF SERVICE) PADA JARINGAN INTERNET (STUDI KASUS : UPT LOKA UJI TEKNIK PENAMBANGAN JAMPANG KULON-LIPI),” 2016. https://dx.doi.org/10.28932/jutisi.v2i2.454

I. S. N. Nisa, Rahmat Miyarno Saputro, Tegar Fatwa Nugroho, and Alfirna Rizqi Lahitani, “Analisis Quality of Service (QoS) Menggunakan Standar Parameter Tiphon pada Jaringan Internet Berbasis Wi-Fi Kampus 1 Unjaya,” Teknomatika: Jurnal Informatika dan Komputer, vol. 17, no. 1, pp. 1–9, Apr. 2024, doi: 10.30989/teknomatika.v17i1.1307.




DOI: http://dx.doi.org/10.62870/setrum.v14i1.29172