Prototype of blood sugar measuring instrument with non invasive method using near infrared
Abstract
Keywords
Full Text:
PDFReferences
Kementrian Kesehatan Republik Indonesia. (2013). Diabetes Melitus Penyebab Kematian Nomor 6 di Dunia” [Online]. Available: http://www.depkes.go.id. [Accessed: 21-Feb-2018].
Kementrian Kesehatan Republik Indonesia. (2016). Mari Kita Cegah Diabetes dengan Cerdik,”[Online]. Available: http://www.depkes.go.id. [Accessed: 21-Feb-2018]
Pande, M. C., & Joshi, A. K., (2013). Non-invasive Optical Blood Glucose Measurement. International Journal of Engineering Research and Applications (IJERA), Vol. 3, No. 4, pp. 129-131.
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2014). Near-infrared LED based non-invasive blood glucose sensor. In 2014 International Conference on Signal Processing and Integrated Networks, SPIN 2014 (pp. 591-594). Article 6777023 (2014 International Conference on Signal Processing and Integrated Networks, SPIN 2014). IEEE. https://doi.org/10.1109/spin.2014.6777023.
Khairunisa, Z., Irzaman, I., Arief, A. (2014). Rancang Bangun Alat Ukur Kadar Gula Darah Non-Invasive Berbasis Sensor Fotodioda. Bogor Agricultural University (IPB). http://repository.ipb.ac.id/handle/123456789/73445
Bobade, R. D., & Patil, M. S. (2016). Non-invasive Blood Glucose Level Monitoring System for Diabetic Patients using Near-Infrared Spectroscopy. Computer Science and Information Technology, 4.
Olokoba, A. B., Obateru, O. A., & Olokoba, L. B. (2012). Type 2 diabetes mellitus: a review of current trends. Oman medical journal, 27(4), 269–273. https://doi.org/10.5001/omj.2012.68
Saleh, G., Alkaabi, F., Al-Hajhouj, N., Al-Towailib, F., & Al-Hamza, S. (2018). Design of non-invasive glucose meter using near-infrared technique. Journal of medical engineering & technology, 42(2), 140–147. https://doi.org/10.1080/03091902.2018.1439114
Lai, J., Huang, S., Lin, R., & Tsai, S. (2016). Design a non-invasive near-infrared LED blood glucose sensor. 2016 International Conference on Applied System Innovation (ICASI), 1-4.
Kaur, J., Kumar, J., Sardana, H.K., Bhatnagar, R., & Mehla, N.S. (2009). NON INVASIVE BLOOD GLUCOSE MEASUREMENT USING OPTICAL METHOD: FEASIBILITY STUDY AND DESIGN ISSUES.
Lawand, K., Parihar, M., & Patil, S. (2015). Design and development of infrared LED based non invasive blood glucometer. 2015 Annual IEEE India Conference (INDICON), 1-6.
DOI: http://dx.doi.org/10.62870/tjst.v20i1.23146
Refbacks
- There are currently no refbacks.
Copyright (c) 2024 Teknika: Jurnal Sains dan Teknologi
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Teknika: Jurnal Sains dan Teknologi is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.