Estimated acceptance of ovarian radiation absorbed dose in abdominal examination using the 10 kV rule method based on Caldose_X Software
Abstract
Radiation exposure to the ovaries due to abdominal radiology is unavoidable given its location in the lower abdomen. Ovaries are organs that have a high level of sensitivity to radiation. One of the efforts used in the application of radiation protection optimization is the use of the 10 kV rule method. This study aimed to determine the estimated reception of ovarian radiation dose on abdominal radiology examination. The examination was carried out by anteroposterior (AP) projection of the female body phantom (FAX06) using Caldose_X software. The beam variation is set from 60kV/32mAs to 100kV/2mAs. The results of the ovarian radiation dose examination were: 0.484mGy for 60kV/32mAs, 0.402mGy for 70kV/16mAs, 0.309mGy for 80kV/8mAs, 0.227mGy for 90kV/4mAs, and 0.154mGy for 100kV/2mAs. When compared with the radiation dose limit for the abdominal examination set by BAPETEN, the data for this study were much smaller. Likewise, when compared with the reference results of previous studies, the data on ovarian radiation dose reception in this study were still within safe limits.
Keywords
Full Text:
PDFReferences
Achuka, J. A., Aweda, M. A., Usikalu, M. R., & Aborisade, C. A. (2020). Assessment of Patient Absorbed Radiation Dose during Hysterosalpingography: A Pilot Study in Southwest Nigeria. Journal Biomed Physics Engineering, 10(2), 131-140.
Akhadi, M. (2000). Dasar-dasar Proteksi Radiasi. Jakarta: Rineka Cipta.
Ball, J., & Price. (1989). Chesney’s Radiography Imagin. Oxford: Blackwell Scientific.
Bima, E. A., Maslebu, G., & Munenggar, J. (2016). Estimasi Dosis Radiasi Janin pada Pemeriksaan Anterior-Posterior (AP) Abdomen dengan X-ray Konvensional. Seminar Nasional Masif II Tahun 2016 (pp. 189-194). Semarang: Universitas PGRI Semarang.
Bushberg, J. T., Siebert, J. A., Leidholth, E. M., & Boone, J. M. (2002). The Essential Physics of Medical Imaging. Philadelphia: Lippincott Williams & Wilkins.
Bushong, S. C. (2013). Radiologic Science for Technologists (10th Edition). United state of America: Mosby Company.
Darmini, Masrochah, S., & Daryati, S. (2013). Analisis Dosis Radiasi pada Organ Reproduksi Wanita pada Pemeriksaan Histerosalfingografi sebagai Penunjang Keselamatan Radiasi pada Unit Pelayanan Radiologi. LINK, 427-436.
Handoko, B. D., Nurfathoni, M. A., & Sulistiyadi, A. H. (2019). Analisa Dosis radiasi Organ Reproduksi pada Pemeriksaan Radiografi Abdomen Proyeksi Anteroposterior dengan Penggunaan Metode 10 kV Rule. JImeD, 5(1), 43-49.
Indrati, R., Sumala, R., Sudiyono, & Daryati, S. (2017). Analisa Penerimaan Dosis Serap Organ Reproduksi pada Pemeriksaan Radiografi Abdomen Antara Penggunaan Teknik kV Rendah dan Teknik kV Tinggi. Jakarta: Bapeten.
Kramer, R., Khoury, H. J., & Vieira, J. W. (2008). CALDose_X - A Software Tool for the Assessment of Organ and Tissue Absorbed Doses, Effective Dose and Cancer Risks in Diagnostic Radiology. Physics in Medicine and Biology, 6437.
Kumar, A., & Kumar, P. (2011). Evaluation On X-Ray Exposure Parameter Considering Tube Voltage and Exposure Time.
Pearce, E. C. (2013). Anatomi dan Fisiologi Untuk Paramedis. Jakarta: Gramedia.
Plats, V. D. (1980). Medical X-Ray Techniques In Diagnostic Radiology. Netherland: Martinus Nijhoff Publisher.
Simon, S. L., Weinstock, R. M., Doody, M. M., Neton, J., Wenzl, T., Stewart, P., . . . Linet, M. (2006). Estimating historical radiation doses to a cohort of U.S. radiologic technologists. Radiation Research, 174-192.
Statkiewicz, M. A., Visconti, P. J., Ritenour, E. R., & Haynes, K. (2017). Radiation Protection In Medical Radiography. Canada: Mosby.
Vassileva, J. (2002). A Phantom for Dose Image Quality Optimization in Chest Radiography. The British Journal of Radiology, 837-842.
Yousef, M., Tambul, J. Y., & Sulieman, A. (2014). Radiation dose measurements during hysterosalpingography. Sudan Medical Monitor, 15-18
DOI: http://dx.doi.org/10.30870/gravity.v8i2.15734
Refbacks
- There are currently no refbacks.
Gravity has been indexed by:
| Gravity : Jurnal Ilmiah Penelitian dan Pembelajaran Fisika is publihed by Department of Physics Education, Universitas Sultan Ageng Tirtayasa jointly with Physical Society of Indonesia (PSI) | |
Gravity : Jurnal Ilmiah Penelitian dan Pembelajaran Fisika is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License Copyright © 2020, Gravity: Jurnal Ilmiah Penelitian dan Pembelajaran Fisika. |