IDENTIFICATION OF INDUCED DRAFT FAN (IDF) DAMAGE IN BOILER WASTE GAS SYSTEM

Yasdin Yasdin, alimin alimin, Siti Ramasih

Abstract


Induced Draft Fan (IDF) is a fan that sucks air from inside the boiler out to the chimney, producing negative pressure on the boiler, keeping the circulation of combustion air in the boiler normal. IDF is one of the main components in the exhaust gas system which serves to maintain the temperature and vacuum of the furnace in the boiler. This report will identify IDF damage using vibration indication control instruments by looking at vibration indication trending data through the Distributed Control System (DCS) in the Central Control Room (CCR). The results of the trending data will then be identified whether the vibration in Induced Draft Fan has increased, if the vibration ≥ 5.6 mm/s is declared an alarm and if the vibration ≥ 7.1 mm/s then the unit trip or must be stopped. Based on the results of research during industrial practice in Banten 2 PLTU Labuan there were 2 conditions in the IDF, namely when there was a disturbance with a height of X and Y side vibrations of 22.5 mm/s, and conditions after improvement with the height of X vibration side that is, an average of 4.2 mm/s and Y side averaging 4.1 mm/s. The high vibration is affected by the damage of several IDF components, caused by the amount of ash remaining combustion that enters the IDF which causes abrasion of the impeller blade.


Keywords


Induced, Draft, Fan, Indikasi, Vibrasi

Full Text:

PDF

References


Harjono, R. N., Sukmadi, T., & Karnoto. (2013). Pemanfaatan Spektrum Vibrasi Untuk Mengindikasikan Kerusakan Pada Motor Induksi Di Pltu Indramayu 3 X 330 Mw. Pemanfaatan Spektrum Vibrasi Untuk Mengindikasikan Kerusakan Pada Motor Induksi Di Pltu Indramayu 3 X 330 Mw, 9.

Nurul, K. M., & Akhmad, H. (2010). Simulasi Sistem Kontrol Induced Draft Fan Sebagai Furnace Pressure Control Pada Boiler Pltu Paiton Unit 7 &8. EEPIS Final Project, (Id), 1–5.

Operasi, B. (2016c). Bidang OperasI Level Kompetensi 2 Pengoperasian Induced Draft Fan PT. Indonesia Power.

Setyawan, H. P., & Suryadi, D. (2018). Analisis Karakteristik Vibrasi pada Paper Dryer Machine untuk Deteksi Dini Kerusakan Spherical Roller Bearing. Rotasi, 20(2), 110. https://doi.org/10.14710/rotasi.20.2.110-117

Yustika, F., Putri, K., Nainggolan, B., & Jannus, P. (2017). ISSN 2085-2762 Seminar Nasional Teknik Mesin Politeknik Negeri Jakarta Studi Vibrasi Pada Induced Draft Fan Di Pltu Indramayu Unit 1 ISSN 2085-2762 Seminar Nasional Teknik Mesin Politeknik Negeri Jakarta. (September), 432–440.




DOI: http://dx.doi.org/10.30870/vanos.v4i1.6111

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License